Compliance and audits
Measuring instruments: types, uses and how each is calibrated
A measuring instrument is a device used to make measurements, alone or with other devices, such as a caliper or a multimeter. Measuring instruments are grouped by the quantity they measure, and each group is calibrated against its own kind of reference standard.
On this page
What is a measuring instrument?
The International Vocabulary of Metrology (VIM, JCGM 200:2012, entry 3.1) describes a measuring instrument as a device for making measurements, used on its own or together with supplementary devices. One that can be used on its own also counts as a measuring system (entry 3.2).
The VIM splits measuring instruments into two kinds. An indicating instrument gives an output, such as a reading on a display, that carries the value of what it measures. A material measure holds a value instead, like a test weight or a gauge block. Many instruments also contain a measuring transducer, the part that turns one quantity into another.
| Kind | What it does | Examples |
|---|---|---|
| Indicating measuring instrument (VIM 3.3) | Gives an output signal that carries the value of the quantity measured, shown on a display or passed on to other devices | Voltmeter, micrometer, thermometer, electronic balance |
| Material measure (VIM 3.6) | Reproduces or supplies a quantity with an assigned value, permanently while it is in use | Standard weight, gauge block, ruler, standard resistor, certified reference material |
| Measuring transducer (VIM 3.7) | Converts an input quantity into an output quantity by a known relation | Thermocouple, current transformer, pH electrode, Bourdon tube |
| Measuring system (VIM 3.2) | One or more instruments, often with other devices, put together to give measured values | A load cell with its indicator, a coordinate measuring machine with its probe and software |
Types of measuring instruments by what they measure
The usual way to group measuring instruments is by the quantity they measure, because each quantity has its own units, references and calibration methods. The BIPM key comparison database sorts calibration services the same way, by metrology area. The table uses the groups that shops and labs meet most often, with the reference each group is usually calibrated against.
| What it measures | Common instruments | Usually calibrated against |
|---|---|---|
| Length and dimension | Calipers, micrometers, dial indicators, height gauges, gauge blocks, coordinate measuring machines | Gauge blocks, setting rings and other length standards |
| Mass | Scales and balances, test weights | Test weights of a known OIML R 111 class |
| Force, torque and hardness | Load cells, force gauges, torque wrenches, hardness testers | A deadweight machine or reference load cell, a torque calibration system, hardness reference blocks |
| Pressure and vacuum | Pressure gauges, pressure transmitters, vacuum gauges | A deadweight tester or a more accurate reference gauge |
| Temperature and humidity | Thermometers, thermocouples, infrared thermometers, hygrometers | A reference thermometer in a bath or dry block, a blackbody source, a humidity generator |
| Electrical | Multimeters, clamp meters | A multifunction calibrator, with a current coil for clamp meters |
| Flow and air speed | Liquid and gas flow meters, anemometers | A weighing tank, a prover or a master meter, and a wind tunnel for anemometers |
| Time, frequency and speed | Stopwatches, timers, frequency counters, tachometers | Time and frequency references traceable to the SI second |
| Chemistry | pH meters, refractometers | Buffer solutions, distilled water and reference solutions |
| Sound, vibration and light | Sound level meters, accelerometers, light meters | A sound calibrator, a reference accelerometer, a reference photometer or standard lamp |
Length and dimension: calipers, micrometers and gauges
Dimensional instruments measure lengths, diameters, depths, heights and gaps. They are the first instruments most shops own. Precise length measurements are made at 20 °C, the reference temperature ISO 1 sets for dimensional specifications, or corrected to it.
| Instrument | What it is used for |
|---|---|
| Caliper (vernier, dial or digital) | Outside, inside, depth and step measurements over a wide range |
| Micrometer | Outside diameters and thicknesses, more accurately than a caliper |
| Dial indicator and dial test indicator | Small displacements, runout and flatness, used as a comparator |
| Dial bore gauge | Bore diameters, taper and out-of-round, set on a ring or gauge blocks |
| Gauge blocks | Reference lengths for setting and calibrating other instruments |
| Go/no-go gauges | Checking that a hole, shaft or thread is within its limits, without a reading |
| Height gauge | Heights and marking out from a surface plate |
| Feeler gauges | Gaps and clearances between parts |
| Coordinate measuring machine (CMM) | Size, position and form of complex parts in three dimensions |
| Rules and tape measures | Rough lengths and layout |
- Caliper calibration
- Vernier caliper reading practice
- Micrometer calibration
- Inside micrometer and bore micrometer
- Dial indicator calibration
- Dial bore gauge
- Gauge block calibration
- Go/no-go gauges
- Height gauge
- Surface plate calibration
- Engineer's square and straightedge
- Bevel protractor
- Feeler gauges
- Coordinate measuring machine (CMM)
- Optical comparator (profile projector)
- Surface roughness tester calibration
- Hole and shaft fits: clearance, transition and press
Mass, force, torque and hardness
Scales and balances measure mass, and test weights are the material measures they are checked with. Force and torque instruments measure push, pull and twist. Hardness testers measure how a material resists an indenter pressed in with a set force. In the BIPM's structure all of these belong to one committee, the Consultative Committee for Mass and Related Quantities (CCM), which also covers pressure and fluid flow.
| Instrument | What it is used for |
|---|---|
| Scale or balance | Weighing parts, materials and products |
| Test weights | Reference masses for checking and calibrating scales |
| Load cell and force gauge | Force in testing machines, presses and weighing systems |
| Torque wrench | Tightening fasteners to a set torque |
| Hardness tester (Rockwell, Brinell, Vickers) | A material's hardness, from the indentation an indenter leaves under a set force |
- Scale calibration
- Test weight calibration
- Load cell calibration
- Force gauge calibration
- Testing machine verification
- Torque wrench calibration
- Hardness tester calibration
Pressure and vacuum
Pressure gauges and transmitters measure the pressure of gases and liquids in process lines, hydraulics and compressed air. They are calibrated against a deadweight tester or a more accurate reference gauge, with the pressure first rising and then falling.
| Instrument | What it is used for |
|---|---|
| Bourdon tube pressure gauge | Reading line, tank and hydraulic pressure on the spot |
| Digital pressure gauge | Field readings, and a reference for checking other gauges |
| Pressure transmitter | Sending a pressure signal, such as 4 mA to 20 mA, to a control system |
| Vacuum gauge | Pressures below atmospheric pressure |
Temperature and humidity
Temperature is measured by contact, with a probe at the same temperature as the object, or without contact, from the infrared radiation the object gives off. The BIPM's committee for thermometry (CCT) also covers humidity. Relative humidity depends strongly on temperature, and a thermo-hygrometer reports both, so both of its readings need checking.
| Instrument | What it is used for |
|---|---|
| Liquid-in-glass or digital thermometer | General temperature readings in labs and processes |
| Resistance thermometer (Pt100) and thermocouple | Temperature sensors in ovens, baths, processes and test rigs |
| Infrared thermometer | Surface temperature without contact |
| Hygrometer and thermo-hygrometer | Relative humidity and dew point in rooms, stores and test chambers |
Electrical: multimeters and clamp meters
Electrical instruments measure voltage, current, resistance and related quantities. A digital multimeter covers most of them on a bench or in the field, and a clamp meter measures current in a wire without breaking the circuit. A multimeter is calibrated against a multifunction calibrator, which supplies known values of each quantity. A clamp meter's current function is calibrated through its jaws, with a calibrator and a current coil or with a known current in a single conductor.
Flow and air speed
Flow meters measure how much liquid or gas passes per unit of time. They are calibrated at several steady flows against a weighing tank, a volumetric tank, a prover or a master meter, and the result holds for the fluid and the flow range used. Anemometers measure air speed, in ducts or outdoors. National laboratories such as NIST calibrate them in a wind tunnel against a laser Doppler anemometer.
Time, frequency and speed
Stopwatches, timers and frequency counters measure time intervals and frequency, and tachometers measure rotational speed. Their references are time and frequency standards traceable to the SI second. NIST's guide to stopwatch and timer calibrations (SP 960-12) describes three methods: comparison with a time signal, the totalize method against a laboratory time interval reference, and measuring the instrument's time base frequency directly.
Chemistry: pH and refractive index
Chemical instruments measure a property of a sample. A pH meter is calibrated with buffer solutions of known pH at a known temperature. A refractometer reads refractive index or a sugar scale such as Brix. It is set to zero with distilled water and checked with reference solutions, such as sucrose solutions, at a stated temperature.
| Instrument | What it is used for |
|---|---|
| pH meter | Acidity or alkalinity of water, plating baths, food and process liquids |
| Refractometer | Sugar content in Brix, salinity and the concentration of machining coolant |
Sound, vibration and light
A sound level meter is checked with a sound calibrator before and after each set of measurements and tested in a laboratory to IEC 61672-3. Accelerometers and other vibration transducers are calibrated by comparison with a reference transducer on a vibration exciter, as ISO 16063-21 describes. Light meters measure illuminance in lux and are calibrated against a reference photometer or a standard lamp.
Resolution vs accuracy: what is the difference?
Resolution is the smallest change an instrument can show. Accuracy is how close its reading comes to the true value. More digits on a display do not make an instrument more accurate.
In VIM terms, resolution (4.14) is the smallest change in what is being measured that visibly moves the reading. Makers state accuracy as a maximum permissible error or an accuracy class (VIM 4.26 and 4.25). A calibration then gives the actual error at each test point, together with its measurement uncertainty, which says how far that error itself can be trusted.
How do you choose a measuring instrument?
These points are common good practice rather than the requirements of one standard.
- Range. The instrument has to cover the values you measure, ideally without working near the bottom of its range, where fixed errors weigh most.
- Accuracy against the tolerance. Its uncertainty in use should be small compared with the tolerance you check. The test uncertainty ratio puts a number on that.
- Resolution. It should be fine enough to show changes well inside the tolerance.
- Conditions of use. Heat, dirt and vibration decide what survives on a shop floor, and electrical meters need a safety category that suits the circuit.
- Calibration. Before you buy, check who can calibrate it, in-house or at a lab, and how.
How are measuring instruments kept accurate?
Instruments drift with use, wear and time. So they are calibrated at set intervals against reference standards that have their own calibration, in an unbroken chain back to the SI, which is metrological traceability (VIM 2.41). Where traceability is required, ISO 9001 clause 7.1.5.2 expects instruments to be calibrated or verified against references that trace back to national or international standards, identified so that their status can be determined, and protected from adjustment, damage or deterioration.
No standard sets one interval for all instruments. Start from the maker's advice or your customer's requirement, then lengthen or shorten it from each instrument's own calibration results, as ILAC-G24:2022 / OIML D 10:2022 describes. Between calibrations, simple checks against a known reference catch a damaged instrument early.
Where Axiospec fits
Axiospec is calibration management software. It keeps each measuring instrument with its calibrations, as-found and as-left readings, certificates and next due date, and puts an instrument in quarantine when a failed calibration is accepted. The free plan covers up to 50 active instruments.
Common questions
- What is a measuring instrument?
- It is a device used to make measurements, alone or with other devices, as the VIM (JCGM 200:2012, entry 3.1) puts it. It either gives a reading, like a thermometer, or holds a fixed value, like a gauge block or a test weight.
- What are the main types of measuring instruments?
- They are grouped by what they measure: length and dimension, mass, force and torque, pressure, temperature and humidity, electrical quantities, flow, time and speed, chemical properties such as pH, and sound and light. Each group has its own reference standards and calibration methods.
- What is the difference between resolution and accuracy?
- Resolution is the smallest change an instrument can show. Accuracy is how close its reading is to the true value. An instrument can have a fine resolution and still read wrong, which only a calibration against a better reference shows.
- Is a gauge block a measuring instrument?
- Yes. The VIM calls it a material measure, a measuring instrument that holds a fixed, assigned value while it is in use. Test weights, rulers and standard resistors are material measures too.
- What is the difference between a measuring instrument and a measuring system?
- A measuring system is one or more measuring instruments, often with other devices, put together to give measured values (VIM 3.2). An instrument that can be used on its own, such as a digital thermometer, is also a measuring system.
- How often should measuring instruments be calibrated?
- No standard sets one interval for all of them. Start from the maker's recommendation or your customer's requirement, then adjust each instrument's interval from its own calibration results, its use and its environment.
Put it into practice
Got a gage list? Send it over and we load it for you, usually in a couple of business days. Free on every plan. Then log every calibration to a tamper-evident audit trail and produce records on demand.
Axiospec is a documentation and workflow tool. It helps you keep clean, traceable, audit-ready records. Certification depends on your own processes, scope and assessor.
Take the audit-prep checklist with you
First the checklist, with each item phrased the way an auditor asks it. Then four short emails with practical tips. You can unsubscribe in one click.
First we email you a link to confirm your address. Nothing else comes until you confirm, and you can unsubscribe from any email after that. See our Privacy Policy.