Skip to content

Compliance and audits

Measuring instruments: types, uses and how each is calibrated

9 min read Published

A measuring instrument is a device used to make measurements, alone or with other devices, such as a caliper or a multimeter. Measuring instruments are grouped by the quantity they measure, and each group is calibrated against its own kind of reference standard.

On this page

What is a measuring instrument?

The International Vocabulary of Metrology (VIM, JCGM 200:2012, entry 3.1) describes a measuring instrument as a device for making measurements, used on its own or together with supplementary devices. One that can be used on its own also counts as a measuring system (entry 3.2).

The VIM splits measuring instruments into two kinds. An indicating instrument gives an output, such as a reading on a display, that carries the value of what it measures. A material measure holds a value instead, like a test weight or a gauge block. Many instruments also contain a measuring transducer, the part that turns one quantity into another.

Kinds of measuring device in the VIM (the examples in the first three rows are the VIM's own)
KindWhat it doesExamples
Indicating measuring instrument (VIM 3.3)Gives an output signal that carries the value of the quantity measured, shown on a display or passed on to other devicesVoltmeter, micrometer, thermometer, electronic balance
Material measure (VIM 3.6)Reproduces or supplies a quantity with an assigned value, permanently while it is in useStandard weight, gauge block, ruler, standard resistor, certified reference material
Measuring transducer (VIM 3.7)Converts an input quantity into an output quantity by a known relationThermocouple, current transformer, pH electrode, Bourdon tube
Measuring system (VIM 3.2)One or more instruments, often with other devices, put together to give measured valuesA load cell with its indicator, a coordinate measuring machine with its probe and software

Types of measuring instruments by what they measure

The usual way to group measuring instruments is by the quantity they measure, because each quantity has its own units, references and calibration methods. The BIPM key comparison database sorts calibration services the same way, by metrology area. The table uses the groups that shops and labs meet most often, with the reference each group is usually calibrated against.

Common types of measuring instruments and how each type is calibrated
What it measuresCommon instrumentsUsually calibrated against
Length and dimensionCalipers, micrometers, dial indicators, height gauges, gauge blocks, coordinate measuring machinesGauge blocks, setting rings and other length standards
MassScales and balances, test weightsTest weights of a known OIML R 111 class
Force, torque and hardnessLoad cells, force gauges, torque wrenches, hardness testersA deadweight machine or reference load cell, a torque calibration system, hardness reference blocks
Pressure and vacuumPressure gauges, pressure transmitters, vacuum gaugesA deadweight tester or a more accurate reference gauge
Temperature and humidityThermometers, thermocouples, infrared thermometers, hygrometersA reference thermometer in a bath or dry block, a blackbody source, a humidity generator
ElectricalMultimeters, clamp metersA multifunction calibrator, with a current coil for clamp meters
Flow and air speedLiquid and gas flow meters, anemometersA weighing tank, a prover or a master meter, and a wind tunnel for anemometers
Time, frequency and speedStopwatches, timers, frequency counters, tachometersTime and frequency references traceable to the SI second
ChemistrypH meters, refractometersBuffer solutions, distilled water and reference solutions
Sound, vibration and lightSound level meters, accelerometers, light metersA sound calibrator, a reference accelerometer, a reference photometer or standard lamp

Length and dimension: calipers, micrometers and gauges

Dimensional instruments measure lengths, diameters, depths, heights and gaps. They are the first instruments most shops own. Precise length measurements are made at 20 °C, the reference temperature ISO 1 sets for dimensional specifications, or corrected to it.

Length and dimension instruments
InstrumentWhat it is used for
Caliper (vernier, dial or digital)Outside, inside, depth and step measurements over a wide range
MicrometerOutside diameters and thicknesses, more accurately than a caliper
Dial indicator and dial test indicatorSmall displacements, runout and flatness, used as a comparator
Dial bore gaugeBore diameters, taper and out-of-round, set on a ring or gauge blocks
Gauge blocksReference lengths for setting and calibrating other instruments
Go/no-go gaugesChecking that a hole, shaft or thread is within its limits, without a reading
Height gaugeHeights and marking out from a surface plate
Feeler gaugesGaps and clearances between parts
Coordinate measuring machine (CMM)Size, position and form of complex parts in three dimensions
Rules and tape measuresRough lengths and layout

Mass, force, torque and hardness

Scales and balances measure mass, and test weights are the material measures they are checked with. Force and torque instruments measure push, pull and twist. Hardness testers measure how a material resists an indenter pressed in with a set force. In the BIPM's structure all of these belong to one committee, the Consultative Committee for Mass and Related Quantities (CCM), which also covers pressure and fluid flow.

Mass, force, torque and hardness instruments
InstrumentWhat it is used for
Scale or balanceWeighing parts, materials and products
Test weightsReference masses for checking and calibrating scales
Load cell and force gaugeForce in testing machines, presses and weighing systems
Torque wrenchTightening fasteners to a set torque
Hardness tester (Rockwell, Brinell, Vickers)A material's hardness, from the indentation an indenter leaves under a set force
Tip: For Rockwell testers, ISO 6508-2:2023 describes two kinds of verification. Direct verification checks the machine itself, such as its test force and its depth measurement. Indirect verification tests reference hardness blocks of known hardness to show how well the machine measures.

Pressure and vacuum

Pressure gauges and transmitters measure the pressure of gases and liquids in process lines, hydraulics and compressed air. They are calibrated against a deadweight tester or a more accurate reference gauge, with the pressure first rising and then falling.

Pressure instruments
InstrumentWhat it is used for
Bourdon tube pressure gaugeReading line, tank and hydraulic pressure on the spot
Digital pressure gaugeField readings, and a reference for checking other gauges
Pressure transmitterSending a pressure signal, such as 4 mA to 20 mA, to a control system
Vacuum gaugePressures below atmospheric pressure

Temperature and humidity

Temperature is measured by contact, with a probe at the same temperature as the object, or without contact, from the infrared radiation the object gives off. The BIPM's committee for thermometry (CCT) also covers humidity. Relative humidity depends strongly on temperature, and a thermo-hygrometer reports both, so both of its readings need checking.

Temperature and humidity instruments
InstrumentWhat it is used for
Liquid-in-glass or digital thermometerGeneral temperature readings in labs and processes
Resistance thermometer (Pt100) and thermocoupleTemperature sensors in ovens, baths, processes and test rigs
Infrared thermometerSurface temperature without contact
Hygrometer and thermo-hygrometerRelative humidity and dew point in rooms, stores and test chambers

Electrical: multimeters and clamp meters

Electrical instruments measure voltage, current, resistance and related quantities. A digital multimeter covers most of them on a bench or in the field, and a clamp meter measures current in a wire without breaking the circuit. A multimeter is calibrated against a multifunction calibrator, which supplies known values of each quantity. A clamp meter's current function is calibrated through its jaws, with a calibrator and a current coil or with a known current in a single conductor.

Flow and air speed

Flow meters measure how much liquid or gas passes per unit of time. They are calibrated at several steady flows against a weighing tank, a volumetric tank, a prover or a master meter, and the result holds for the fluid and the flow range used. Anemometers measure air speed, in ducts or outdoors. National laboratories such as NIST calibrate them in a wind tunnel against a laser Doppler anemometer.

Time, frequency and speed

Stopwatches, timers and frequency counters measure time intervals and frequency, and tachometers measure rotational speed. Their references are time and frequency standards traceable to the SI second. NIST's guide to stopwatch and timer calibrations (SP 960-12) describes three methods: comparison with a time signal, the totalize method against a laboratory time interval reference, and measuring the instrument's time base frequency directly.

Chemistry: pH and refractive index

Chemical instruments measure a property of a sample. A pH meter is calibrated with buffer solutions of known pH at a known temperature. A refractometer reads refractive index or a sugar scale such as Brix. It is set to zero with distilled water and checked with reference solutions, such as sucrose solutions, at a stated temperature.

Chemistry instruments
InstrumentWhat it is used for
pH meterAcidity or alkalinity of water, plating baths, food and process liquids
RefractometerSugar content in Brix, salinity and the concentration of machining coolant

Sound, vibration and light

A sound level meter is checked with a sound calibrator before and after each set of measurements and tested in a laboratory to IEC 61672-3. Accelerometers and other vibration transducers are calibrated by comparison with a reference transducer on a vibration exciter, as ISO 16063-21 describes. Light meters measure illuminance in lux and are calibrated against a reference photometer or a standard lamp.

Resolution vs accuracy: what is the difference?

Resolution is the smallest change an instrument can show. Accuracy is how close its reading comes to the true value. More digits on a display do not make an instrument more accurate.

In VIM terms, resolution (4.14) is the smallest change in what is being measured that visibly moves the reading. Makers state accuracy as a maximum permissible error or an accuracy class (VIM 4.26 and 4.25). A calibration then gives the actual error at each test point, together with its measurement uncertainty, which says how far that error itself can be trusted.

How do you choose a measuring instrument?

These points are common good practice rather than the requirements of one standard.

  • Range. The instrument has to cover the values you measure, ideally without working near the bottom of its range, where fixed errors weigh most.
  • Accuracy against the tolerance. Its uncertainty in use should be small compared with the tolerance you check. The test uncertainty ratio puts a number on that.
  • Resolution. It should be fine enough to show changes well inside the tolerance.
  • Conditions of use. Heat, dirt and vibration decide what survives on a shop floor, and electrical meters need a safety category that suits the circuit.
  • Calibration. Before you buy, check who can calibrate it, in-house or at a lab, and how.

How are measuring instruments kept accurate?

Instruments drift with use, wear and time. So they are calibrated at set intervals against reference standards that have their own calibration, in an unbroken chain back to the SI, which is metrological traceability (VIM 2.41). Where traceability is required, ISO 9001 clause 7.1.5.2 expects instruments to be calibrated or verified against references that trace back to national or international standards, identified so that their status can be determined, and protected from adjustment, damage or deterioration.

No standard sets one interval for all instruments. Start from the maker's advice or your customer's requirement, then lengthen or shorten it from each instrument's own calibration results, as ILAC-G24:2022 / OIML D 10:2022 describes. Between calibrations, simple checks against a known reference catch a damaged instrument early.

Where Axiospec fits

Axiospec is calibration management software. It keeps each measuring instrument with its calibrations, as-found and as-left readings, certificates and next due date, and puts an instrument in quarantine when a failed calibration is accepted. The free plan covers up to 50 active instruments.

Common questions

What is a measuring instrument?
It is a device used to make measurements, alone or with other devices, as the VIM (JCGM 200:2012, entry 3.1) puts it. It either gives a reading, like a thermometer, or holds a fixed value, like a gauge block or a test weight.
What are the main types of measuring instruments?
They are grouped by what they measure: length and dimension, mass, force and torque, pressure, temperature and humidity, electrical quantities, flow, time and speed, chemical properties such as pH, and sound and light. Each group has its own reference standards and calibration methods.
What is the difference between resolution and accuracy?
Resolution is the smallest change an instrument can show. Accuracy is how close its reading is to the true value. An instrument can have a fine resolution and still read wrong, which only a calibration against a better reference shows.
Is a gauge block a measuring instrument?
Yes. The VIM calls it a material measure, a measuring instrument that holds a fixed, assigned value while it is in use. Test weights, rulers and standard resistors are material measures too.
What is the difference between a measuring instrument and a measuring system?
A measuring system is one or more measuring instruments, often with other devices, put together to give measured values (VIM 3.2). An instrument that can be used on its own, such as a digital thermometer, is also a measuring system.
How often should measuring instruments be calibrated?
No standard sets one interval for all of them. Start from the maker's recommendation or your customer's requirement, then adjust each instrument's interval from its own calibration results, its use and its environment.

Put it into practice

Got a gage list? Send it over and we load it for you, usually in a couple of business days. Free on every plan. Then log every calibration to a tamper-evident audit trail and produce records on demand.

Axiospec is a documentation and workflow tool. It helps you keep clean, traceable, audit-ready records. Certification depends on your own processes, scope and assessor.