A go/no-go gauge, also called a limit gauge, checks a part against its two limits without measuring it: the GO member has to fit the part and the NO GO member must not. Calibrating the gauge means measuring the gauge itself, its diameter or pitch diameter at set positions, and comparing the result with its gauge maker's tolerance and its wear limit.

On this page

What is a go/no-go gauge?

A go/no-go gauge is a fixed gauge made to the limits of one feature. Instead of a reading it gives a verdict. The part passes when the GO member fits and the NO GO member does not, which is how makers such as Meyer Gage describe fixed limit gauging. It is quick and needs little training, but it does not tell you where in the tolerance the part sits.

Each gauge has two members, often on one handle. The GO member is made to the maximum material limit of the feature, which is the smallest hole or the largest shaft. The NO GO member is made to the least material limit, the largest hole or the smallest shaft. Thread standards call the second member NOT GO.

The common go/no-go gauges and what each member checks
GaugeChecksGO memberNO GO member
Plain plug gaugeA holeThe smallest hole allowed (lower limit)The largest hole allowed (upper limit)
Plain ring gaugeA shaft or pinThe largest shaft allowed (upper limit)The smallest shaft allowed (lower limit)
Snap gauge (gap gauge)A shaft or a width, from the outsideThe largest size allowedThe smallest size allowed
Thread plug gaugeAn internal threadA full thread form at the maximum material limitThe other limit, the NOT GO (HI) member
Thread ring gaugeAn external threadA full thread form at the maximum material limitThe other limit, the NOT GO (LO) member
Tip: A part that passes the GO member alone is not proven good. An oversize hole takes a GO plug easily, so use both members every time.

How do the GO and NO GO members work?

The two members are designed differently, and the reason is known as Taylor's principle. The GO member stands in for the mating part. It has the full form of the feature at the maximum material limit, so it checks size and form together. A bent pin will not pass through a full-length GO ring even when each of its diameters is within the limits.

The NO GO member checks the other limit one size at a time. Ideally it checks between two opposite points, so that an oval hole cannot hold it out. Gauge maker LMW Schmalkalden applies the principle to thread gauges in its catalogue: a GO thread gauge always carries the full thread profile, and its thread should be at least 80 percent as long as the thread engagement.

Take a 30 H9 hole under the ISO system of limits and fits. Its limits are 30.000 mm and 30.052 mm, so the GO plug is made near 30.000 mm and the NO GO plug near 30.052 mm. Exactly where each member sits in relation to those limits is set by the gauge maker's tolerance and, in the ISO system, by a wear allowance.

Gauge maker's tolerance classes in US practice

A gauge cannot be made to an exact size, so it gets a tolerance of its own. In the US, plain plug gauges are bought by tolerance class. The classes come from ASME B89.1.5, which covers the measurement of plain external diameters for master discs and cylindrical plug gauges. Its companion ASME B89.1.6 covers plain internal diameters for master rings and ring gauges.

XXX is the tightest class and ZZ the widest, and each class grows with the diameter. The table shows the three smallest ranges as gauge maker Pratt & Whitney Measurement Systems publishes them.

US makers place the gauge tolerance inside the part limits. Meyer Gage, for example, gives the GO member of a plug gauge a plus tolerance and the NO GO member a minus tolerance, and reverses both for ring gauges. The gauge tolerance can then cost you some good parts near a limit rather than let bad ones through.

Meyer's rule of thumb gives the gauges 10 percent of the part tolerance, split between the GO and NO GO members. For a hole of 0.250 in +0.004 in, 10 percent is 0.0004 in. Each member gets 0.0002 in, which is class ZZ at that size. Pratt & Whitney calls the 10 percent rule a starting point, not a requirement.

Gauge maker's tolerance by class for the three smallest diameter ranges, in inches, from ASME B89.1.5 as published by Pratt & Whitney Measurement Systems
Diameter, above to includingXXXXXXYZZZ
0.010 to 0.825 in0.0000100.0000200.0000400.0000700.0001000.00020
0.825 to 1.510 in0.0000150.0000300.0000600.0000900.0001200.00024
1.510 to 2.510 in0.0000200.0000400.0000800.0001200.0001600.00032
Tip: In metric terms the ZZ tolerance for the smallest range is about 5 µm and the XXX tolerance about 0.25 µm. A tighter class uses up less of the part tolerance.

Wear allowance in ISO 1938-1

ISO 1938-1 is the international standard for plain limit gauges of linear size. Its second edition was published in May 2026 and replaced the 2015 edition. It covers sizes up to 500 mm, defines the types of plain limit gauge, sets maximum permissible limits for new and for worn gauges and describes how the gauges are used.

In the ISO system the GO member carries a wear allowance. A new GO plug is made larger than the lower limit of the hole by an amount z, and a new GO snap gauge smaller than the upper limit of the shaft by z1. The gauge can then wear for a while before it reaches the limit. The worked example in the table comes from the 2022 catalogue of LMW Schmalkalden, a German gauge maker that works to DIN EN ISO 1938-1.

In this example the tolerance of the NO GO member is centred on the part limit, so a NO GO plug may be slightly larger than the largest hole allowed. That differs from the US convention above. Check which convention your gauges were made to before you judge a certificate, and check which edition of ISO 1938-1 applies.

Worked example from LMW Schmalkalden's catalogue: a limit plug gauge for a 30 H9 hole and a limit snap gauge for a 50 h6 shaft
ItemPlug gauge for a 30 H9 holeSnap gauge for a 50 h6 shaft
Part limits30.000 to 30.052 mm49.984 to 50.000 mm
Wear allowance on the GO memberz = 0.009 mmz1 = 0.0035 mm
Gauge maker's tolerance±0.002 mm±0.002 mm
New GO member30.007 to 30.011 mm49.9945 to 49.9985 mm
NO GO member30.050 to 30.054 mm49.982 to 49.986 mm
Tip: LMW warns that incoming inspection often forgets the wear allowance and rejects good gauges. A new GO plug that measures above the lower limit of the hole is doing what it was made to do. German suppliers such as Hoffmann sell working gauges with this allowance and acceptance gauges without it.

Thread plug and thread ring gauges

Thread gauges follow the same idea with a thread form. For Unified inch threads the US standard is ASME B1.2, whose latest edition is dated 2025. For ISO metric threads it is ISO 1502:1996, ISO general-purpose metric screw threads: Gauges and gauging, which ISO last confirmed in 2021. In the US, ASME B1.16M covers gauges for metric threads.

The GO member checks the functional size of the thread. Errors of pitch and flank angle show up as a change in the pitch diameter when two threads mate, which is why the GO member has the full profile. The NOT GO member checks the other limit and may enter a short way. Under the 1983 edition of ASME B1.2, paragraphs 4.2.1 and 5.2.1, the thread is accepted when a NOT GO plug or ring enters no more than three complete turns, as gauge maker Prittie summarises it. ISO 1502 sets its own rule, so check the standard and edition your drawing calls up.

Thread rings are hard to measure directly, so they are usually set or checked with plugs. ASME B1.2 provides W tolerance setting plugs for adjustable rings, and working gauges are usually made to X tolerance. Some makers, Hemco among them, build setting plugs to X tolerance on pitch diameter and W on lead and flank angle, with W on pitch diameter only when it is ordered, so check the certificate. Makers working to ISO 1502 supply GO and NOT GO check plugs for new rings and wear check plugs for rings in use.

A full check of a thread also needs plain gauges. LMW lists plain limit plug gauges for the minor diameter of internal threads, and plain gap or ring gauges for the major diameter of external threads.

How to use go/no-go gauges without forcing them

A gauge is only as good as the way it is used. The same holds for feeler gauges, which also judge a fit by feel. The maintenance notes of Meyer Gage and the advice of thread gauge maker Hemco Gages come down to a few habits.

  • Clean the gauge and the feature first. Dirt or a burr can make a good part fail or a bad one pass.
  • Let the gauge and the part reach the same temperature. Gauges are calibrated at 20 °C (68 °F), the reference temperature of ISO 1.
  • Turn the gauge slowly into or onto the part with light fingertip pressure. The fit should be snug and unforced. A GO thread plug is not a tap, and forcing it damages the gauge and the part.
  • Use both members every time.
  • Check a gauge that has been dropped before you use it again.
  • After use, clean the gauge, give it a thin film against rust and store it away from heat, moisture and corrosive chemicals.
Tip: Inspectors do not always reach the same verdict with the same gauge. An attribute agreement study measures how often they agree with each other and with a known reference.

How to calibrate plain plug and ring gauges

Calibrating a limit gauge means measuring it. Trying it in a part proves nothing about its size. Plugs and rings are usually measured on a horizontal one-coordinate measuring machine, also called an Abbe comparator, which EURAMET describes as the most widespread method for diameters.

EURAMET Calibration Guide No. 6, Guidelines for the Calibration of Cylindrical Diameter Standards (version 3.0, 2024), sets out three levels of calibration, shown in the table. CEM, the Spanish national metrology institute, published a Spanish translation in 2025. The guide lists go/no-go plugs and rings under the middle level: roundness at three heights, one in the middle and two near the end faces, and the diameter in each of those planes in one common axial section.

The German guideline DKD-R 4-3 Blatt 4.1 from PTB is similar. For a working gauge whose form is known from earlier calibrations, it measures the diameter in three planes and in two directions at right angles. If a diameter has moved by more than the standard uncertainty since the last calibration, a full calibration with roundness and straightness follows.

Measure near 20 °C after the gauge has settled to the room. Report the measured sizes, not only a pass, and compare them with the gauge maker's tolerance for a new gauge or with the wear limit for a gauge in use. In Germany, snap gauges have their own test instruction, VDI/VDE/DGQ 2618 Blatt 4.7, for gap gauges to DIN 2231, DIN 2232 and DIN 2233.

The three calibration levels for cylindrical diameter standards in EURAMET Calibration Guide No. 6
LevelWhat is measuredSuited to
Diameter onlyOne diameter in the nominal direction, two more turned about the axis by about ±10° (or ±1 mm on the circumference, whichever is smaller) and two more about 1 mm above and below it. The mean of the five is reported.Setting standards for two-contact instruments
Diameter and roundnessRoundness in three planes and the diameter in each of them, in one axial section. For a go/no-go gauge the planes are in the middle and near each end face.Setting standards for two-contact and three-contact instruments, and go/no-go plugs and rings
Diameter, roundness, straightness and parallelismAt least three roundness traces, straightness and parallelism in at least two axial sections at right angles, and at least one diameterStandards whose form matters, such as piston and cylinder pairs, and high-accuracy standards

Thread gauges: pitch diameter by the three-wire method

The key size of a thread plug gauge is its pitch diameter. It is measured over three hardened wires of known diameter laid in the thread grooves, two on one side and one on the other, on a measuring machine with a set measuring force. DKD-R 4-3 Blatt 4.8 uses this three-wire method, and EURAMET Calibration Guide No. 10 covers pitch diameter measured by probing with wires or balls.

The wire that touches the flanks exactly at the pitch diameter is called the best-size wire. A 1973 report on thread wires from NBS, now NIST, gives its diameter as half the pitch times the secant of the half angle. For a 60° thread that is 0.57735 times the pitch. The simplified formula for a 60° thread is E = M − 3W + 0.866025 P, where E is the pitch diameter, M the measurement over the wires, W the wire diameter and P the pitch. It leaves out a small correction for the lead angle.

For an M10 × 1.5 thread plug, best-size wires are 0.866 mm, and the pitch diameter comes out at about M − 1.299 mm. The NBS report notes that the result depends on the measuring machine, the contact force, the thread form and the wire diameter, and that any error in the wire diameter is multiplied. Use calibrated wires and the measuring force set for the pitch.

DKD-R 4-3 Blatt 4.8 measures in at least two places along the thread and in two axial sections at right angles. A repeat calibration can find the pitch diameter from the nominal pitch and flank angle, with a second wire size as a check on the angle. A first calibration also measures the pitch and the flank angle, and the fuller scope the guideline recommends adds the major and minor diameters. Thread rings are measured with a two-ball probe under DKD-R 4-3 Blatt 4.9, or checked against setting plugs.

Wear limits and when to retire a gauge

The GO member enters every good part, so it wears. The NO GO member should rarely enter, so it wears far less. Meyer Gage notes that GO gauges need recalibration more often than NO GO gauges for this reason.

Retire a GO member when it reaches its wear limit. Under ISO 1938-1 that limit is a maximum permissible limit for the worn state. A gauge made without a wear allowance, as with the US classes above, has none to spend: once its GO plug wears below its tolerance it can pass undersize holes.

Damage is the other reason. A nick, a burr or rust on a measuring surface changes the fit. Do not use a damaged gauge. Have it repaired by the maker or replace it, and calibrate the repaired or new gauge before it goes back into use.

Record the measured size at each calibration. The trend shows how fast each GO member wears, so you can predict when it will reach its limit and set its interval from that.

How often to calibrate go/no-go gauges

No standard sets one interval. ISO 9001 asks for calibration or verification at specified intervals, or before use. ILAC-G24 and OIML D 10 (2022 edition) list the factors to weigh, among them wear, how much and how hard the equipment is used and its calibration history.

For limit gauges wear is the main driver, and wear follows use. Meyer Gage bases the interval on how often a gauge is used, how abrasive the parts are, the tolerances and the way quality is judged. Hemco Gages adds that gauges in heavy use need calibrating more often. An interval tied to use, such as a number of parts or shifts, follows the wear more closely than a calendar date alone.

Between calibrations, check gauges in heavy use against a reference, and check any gauge after a drop. ISO/IEC 17025:2017 clause 6.4.10 calls these intermediate checks.

As-found results and the record to keep

Record the measured sizes before anything is cleaned up, stoned or adjusted. Those are the as-found readings. When an as-found size is outside the gauge's limits, ISO 9001 clause 7.1.5.2 asks you to determine whether earlier results were adversely affected and to act where needed. A worn GO plug may have passed undersize holes, so review the parts it accepted since its last good calibration and compare the error with the part tolerance.

  • The gauge ID, type, size, class or tolerance, and which member each result belongs to.
  • The measured sizes at each position as found, and for an adjustable ring or snap gauge the setting before and after adjustment.
  • The reference standards used, such as gauge blocks, master rings or thread wires, with their certificate numbers and due dates.
  • The method, the temperature, the uncertainty and the decision rule behind any pass or fail statement.
  • How much wear allowance is left, or how far the GO member is from its wear limit.
  • The date, the person or lab, and the next due date.

How to calibrate a go/no-go gauge, step by step

  1. Check that the measuring machine and the gauge blocks, master rings or thread wires have current certificates and that the room is close to 20 °C.
  2. Clean the gauge and inspect the measuring surfaces for nicks, burrs and rust. Note any damage.
  3. Let the gauge settle to the room temperature on or near the measuring machine.
  4. For a plain plug or ring, measure the diameter of each member at the positions your procedure sets, such as three planes in two directions at right angles.
  5. For a thread plug, measure the pitch diameter over three wires in two or more places along the thread. Check a thread ring with a two-ball probe or against its setting or check plugs.
  6. Record each size as found.
  7. Compare the results with the gauge maker's tolerance and the wear limit, using your documented decision rule.
  8. If an adjustable ring or snap gauge needs resetting, adjust it, repeat the measurement and record the as-left size.
  9. Retire a member that is worn past its limit or damaged beyond repair, and assess the parts it gauged since its last good calibration.
  10. Record the result, the standards used, the uncertainty and the next due date, and label the gauge with its status.

How Axiospec helps with go/no-go gauges

Axiospec is calibration management software. It does not measure gauges or decide whether they pass. The tolerance, the wear limit, the decision rule and the interval stay with you or your lab. Each plug, ring, snap or thread gauge is an instrument on the register, with its calibration history, certificates and next due date.

One calibration record holds up to 100 test points. Each point has a name, a nominal value, a tolerance and the as-found and as-left readings, so both members and every measuring position fit in one record. On an in-house calibration, a final reading outside its tolerance sets the result to Fail, and recording a pass anyway takes a written reason. An accepted Fail or Damaged result puts the gauge in quarantine. With a standard such as ISO 9001 or ISO/IEC 17025 selected for the workspace, a Fail, a Damaged, or a Pass with an as-found reading out of tolerance asks you to write down the impact on the parts the gauge checked, and any not yet written show in Needs attention.

Where Gage R&R studies are switched on, a manager can record an attribute agreement study on a gauge's instrument page, and the live demo has a thread plug gauge with one. The free plan covers up to 50 active instruments. A new workspace starts with a 45-day trial of Professional, with room for 1,500 active instruments and no credit card. We load your existing records for you at no charge on every plan.

Common questions

What is a go/no-go gauge?
A go/no-go gauge, or limit gauge, is a fixed gauge made to the two limits of one feature. The part is good when the GO member fits it and the NO GO member does not. It gives a pass or reject verdict, not a measured size.
What is Taylor's principle?
It is the rule behind the design of limit gauges. The GO gauge has the full form of the mating part at the maximum material limit, so it checks size and form together. The NO GO gauge checks the other limit one size at a time.
What do gauge maker tolerance classes such as XX, X, Y, Z and ZZ mean?
They are the tolerance classes for plain plug gauges in ASME B89.1.5. XXX is the tightest and ZZ the widest, and each class widens as the diameter grows. For diameters up to 0.825 in, class ZZ allows 0.0002 in and class X allows 0.00004 in.
How do you calibrate a go/no-go plug gauge?
Measure the diameter of each member on a length measuring machine near 20 °C, at set positions such as three planes along the gauge in two directions at right angles. Compare the sizes with the gauge maker's tolerance for a new gauge or the wear limit for a used one. Thread plugs are measured for pitch diameter by the three-wire method.
How often should go/no-go gauges be calibrated?
No standard sets one interval. GO members wear with use, so base the interval on how often the gauge is used, how abrasive the parts are and the wear seen at past calibrations. Check any gauge that has been dropped before you use it again.
How many turns can a NOT GO thread gauge enter?
Under the 1983 edition of ASME B1.2, a Unified thread is accepted when the NOT GO plug or ring enters no more than three complete turns. ISO 1502 for metric threads sets its own rule, so check the standard and edition your drawing calls up.