Skip to content

Compliance and audits

Feeler gauges: how to measure a gap and how to check the blades

10 min read Published

A feeler gauge is a set of thin steel blades, each made to a marked thickness, for measuring the width of a narrow gap: the thickest blade that slides into the gap with a light, even drag gives the width. The blades are checked by measuring each one with a micrometer or a length comparator and replacing any blade that is out of tolerance, bent or worn.

On this page

What is a feeler gauge?

A feeler gauge, also called a thickness gauge, is a set of hardened steel blades held in a holder. Each blade is made to a known thickness and marked with it, and the set covers a range in small steps. You measure a gap by finding which blade fits it.

It reaches gaps that other instruments cannot. Starrett lists uses such as checking bearing clearances and gear play, fitting pistons and rings and gauging narrow slots. SKF sells feeler gauges for measuring the internal clearance of spherical roller bearings while they are mounted.

A feeler gauge has no scale. Its resolution is the step from one blade to the next, and the result also depends on the feel of the person using it.

Common kinds of feeler gauge
KindWhat it isTypical use
Straight blades in a holderBlades of one width that fold out of a holderGaps and clearances in general
Tapered bladesBlades that narrow toward the tipTight places that a full-width blade cannot reach
Long bladesBlades longer than those of the usual setDeep gaps, such as the clearance in a large bearing
Feeler stockA strip of one thickness, kept in a case and cut to lengthOne-off jobs and shimming
Tip: A gap is at least as wide as the thickest blade that enters it and narrower than the next blade that will not. Pick a set whose steps are fine enough for the tolerance you check.

Which standards cover feeler gauges?

DIN 2275:2014 is the German standard. It covers steel feeler gauges and sets at least 100 mm long, with the dimensions and designation of the blades, their limit deviations, the material, the hardness, the marking and the common sets. The 2014 edition added a second tolerance class, TC2, alongside the first.

JIS B 7524:2008 is the Japanese standard for feeler gauges. In India the standard is IS 3179:2024, which replaced the 1990 edition.

The permitted deviation of a blade is a few micrometres. As one maker's example, SKF gives the blades of its 729865 A set a tolerance of +0.007/−0.005 mm up to 0.10 mm thick and +0.010/−0.005 mm above that. Find the class or tolerance of your own set on its certificate or in the maker's data before you rely on a blade.

How to measure a gap with a feeler gauge

A feeler gauge reading is a judgment of feel, so the method matters as much as the blades. These steps are common workshop practice.

  1. Clean the blade and both surfaces. Oil, a chip or a burr adds to the thickness the blade has to pass.
  2. Pick a blade close to the expected gap and fold the others back into the holder, so only one blade goes in.
  3. Keep the blade flat between the surfaces as you slide it in. A blade held at an angle spans more than its own thickness, so the gap seems smaller than it is.
  4. Find the thickest blade that slides through with a light, even drag. The next thinner blade should move freely and the next thicker one should not go in without force.
  5. Never force a blade. Forcing bends or kinks it, can spring the parts apart and gives a reading wider than the real gap.
  6. Try the gap at more than one place along its length. Gaps are seldom even, and a blade stops at the narrowest point on its path.
  7. Read the thickness marked on the blade, or add up the markings if you used more than one, and record it with the place you measured.
Tip: Feel varies from one person to another. When several people measure the same gaps, have each of them measure the same gap and compare the results, or run a gage R&R study.

Stacking blades and the error it adds

When no single blade fits, you can stack two or more and add their marked thicknesses. Each blade brings its own error, and the errors can add up.

Take three blades of 0.10 mm or less made to SKF's tolerance of +0.007/−0.005 mm. In the worst case the stack is 0.021 mm thicker or 0.015 mm thinner than the sum of its markings. A root-sum-square estimate is smaller, but it assumes the errors are independent, which you cannot take for granted with blades you have not measured.

Anything between the blades adds to that. A film of oil, dust or a burr makes the stack thicker than the sum of its blades, never thinner.

So use as few blades as you can, and the thickest ones that will do. Gauge block stacks follow the same rule, and Mitutoyo's guide advises the fewest and thickest blocks possible. Wipe each blade before you stack it. When the result matters, measure the stack itself with a micrometer.

How to care for a feeler gauge set

A blade is only as good as its condition. These habits keep a set usable for longer.

  • Wipe each blade clean and dry after use, and leave a thin film of oil on it against rust.
  • Fold the blades back into the holder so they cannot bend or kink loose in a drawer.
  • Do not use a blade to scrape, pry or clean out a gap.
  • Store the set away from heat and damp.
  • Take a kinked, bent, rusted or burred blade out of use. Where the holder allows, replace that blade alone.
Tip: The tip of a blade does most of the work and wears first. When you check a set, compare the thickness near the tip with the thickness near the holder.

How to check or calibrate feeler gauge blades

Calibrating a feeler gauge means measuring each blade and comparing the result with its marked thickness and tolerance. Trying a blade in a gap tells you nothing about its thickness. The instrument you measure with needs its own calibration, and its uncertainty has to be small next to the blade tolerance.

There are two usual ways to measure a blade. An outside micrometer with flat anvils is quick. Use its ratchet or friction thimble so the measuring force stays the same, and pick one that reads to 0.001 mm, since one that reads to 0.01 mm cannot resolve a tolerance of a few micrometres. A length comparator set on a gauge block close to the blade's size is more accurate. It measures the blade as a difference from the block, the way gauge blocks themselves are calibrated by comparison.

Measure each blade at several places along its length, at least near the tip, in the middle and near the holder, because wear and damage are uneven. Look along the blade for kinks and bends, and check that the marking can still be read.

Compare each result with the tolerance using your documented decision rule, and work out the test uncertainty ratio (TUR) before you trust a pass. Replace a blade that is out of tolerance, bent, kinked or worn at the tip. A blade thinner than its marking makes gaps read wider than they are.

Checks on a feeler gauge set and what each one finds
CheckHowWhat it finds
ConditionLook along each blade and open and close it in the holderKinks, bends, burrs, rust, worn markings and a loose holder
ThicknessA micrometer that reads to 0.001 mm, or a length comparator set on a gauge block, at several points on each bladeThe error of each blade against its marked thickness
WearCompare the thickness near the tip with the thickness near the holderA tip worn thinner than the rest of the blade

How often to check feeler gauges

No standard sets one interval. ISO 9001 asks for calibration or verification at specified intervals, or before use. ILAC-G24 and OIML D 10 (2022 edition) list the factors to weigh, among them the tendency to wear and drift and how much and how hard the equipment is used (5.1), and describe how to review the interval from its calibration history (6).

Feeler gauges wear with use, so base the interval on how often each set is used and on the wear you find at each check. Look a set over before you use it, and check it again after a drop or when a blade looks bent. ISO/IEC 17025:2017 clause 6.4.10 calls checks between calibrations intermediate checks.

Decide what each set is for. A set used to accept product needs the same control as any other measuring instrument. A set used only to set up a machine, where another instrument checks the result, may need less. Record the decision.

As-found results and the record to keep

Measure and record each blade before any blade is replaced. When a blade is out of tolerance as found, ISO 9001 clause 7.1.5.2 asks you to determine whether earlier results were adversely affected and to act where needed. A blade thinner than its marking made gaps read wider than they were, so review the gaps it set or accepted since the set's last good check.

  • The set ID, the maker and type, and the range and number of blades.
  • The measured thickness of each blade as found, and of any new blade as left.
  • The micrometer, comparator or gauge blocks used, with their certificate numbers and due dates.
  • The temperature, the uncertainty and the decision rule behind any pass or fail statement.
  • Any blade replaced or set retired, and why.
  • The date, the person or lab, and the next due date.

How to check a feeler gauge set, step by step

  1. Check that the micrometer or comparator and the gauge blocks have current certificates and that the room is close to 20 °C.
  2. Clean each blade and let the set settle to the room temperature.
  3. Inspect each blade for kinks, bends, burrs, rust and worn markings, and note any damage.
  4. Measure each blade near the tip, in the middle and near the holder, using the micrometer's ratchet or the comparator.
  5. Record each reading as found and work out its error against the marked thickness.
  6. Compare each error with the tolerance class or the maker's specification, using your documented decision rule.
  7. Replace any blade that fails or is damaged, and measure the new blade before the set goes back into use.
  8. Review the gaps set or accepted with a failed blade since the last good check.
  9. Record the result, the instruments used, the uncertainty and the next due date, and label the set with its status.

How Axiospec helps with feeler gauges

Axiospec is calibration management software. It does not measure blades or decide whether they pass. The tolerance, the decision rule and the interval stay with you or your lab. Each feeler gauge set can be an instrument on the register, with its calibration history, certificates and next due date.

One calibration record holds up to 100 test points. Each has a name, a nominal value, a tolerance and the as-found and as-left readings, so each blade of a set can be its own point. On an in-house calibration, a final reading outside its tolerance turns a Pass into a Fail unless you picked the result yourself, and recording a pass anyway takes a written reason.

An accepted Fail or Damaged result puts the set in quarantine. With a standard such as ISO 9001 or ISO/IEC 17025 selected for the workspace, a Fail, a Damaged, or a Pass with an as-found reading out of tolerance asks you to write down the impact on the gaps it was used for, and any not yet written show in Needs attention. The micrometer or gauge blocks used for the check can sit on the register as reference standards. With a standard selected, each calibration can name the one it used, and the Reverse Traceability card of each lists the instruments it was used to calibrate. The free plan covers up to 50 active instruments. A new workspace starts with a 45-day trial of Professional, with room for 1,500 active instruments and no credit card. We load your existing records for you at no charge on every plan.

Common questions

What is a feeler gauge used for?
A feeler gauge measures the width of a narrow gap, such as a bearing clearance, the play between gears or a narrow slot. You find the thickest blade that slides into the gap with a light drag, and its marked thickness gives the width.
How do you read a feeler gauge?
Read the thickness marked on the blade that fits. The right blade slides in with a light, even drag, the next thinner one moves freely and the next thicker one does not go in without force. If you stack blades, add their markings.
Can you stack feeler gauge blades?
Yes, but each blade adds its own thickness error, and oil or dirt between the blades makes the stack thicker. Use as few blades as you can and the thickest that will do, and measure the stack with a micrometer when the result matters.
How do you calibrate a feeler gauge?
Measure each blade at several points along its length with a micrometer that reads to 0.001 mm or with a length comparator set on a gauge block. Compare each result with the marked thickness and its tolerance, and replace any blade that fails or is bent, kinked or worn.
What standard covers feeler gauges?
DIN 2275:2014 is the German standard for steel feeler gauges and sets, with two tolerance classes. JIS B 7524:2008 is the Japanese standard and IS 3179:2024 the Indian one. Makers also state their own tolerance for each set.
How often should feeler gauges be calibrated?
No standard sets one interval. Base it on how often the set is used and how fast its blades wear, look for damage before each use and check the set again after a drop or when a blade looks bent.

Put it into practice

Got a gage list? Send it over and we load it for you, usually in a couple of business days. Free on every plan. Then log every calibration to a tamper-evident audit trail and produce records on demand.

Axiospec is a documentation and workflow tool. It helps you keep clean, traceable, audit-ready records. Certification depends on your own processes, scope and assessor.