Compliance and audits
Runout in GD&T: how to measure circular and total runout with a dial indicator
Runout is measured by turning the part about its datum axis with an indicator held against the surface, and the full indicator movement (FIM), the highest reading minus the lowest, must be no larger than the runout tolerance. Circular runout is judged one circle at a time, while total runout lets the indicator travel over the whole surface without resetting zero.
On this page
How do you measure runout with a dial indicator?
The method is the same on a bearing seat as on a flange face. The part turns about the axis its datums define, and an indicator held still against the toleranced surface shows how far that surface moves toward it and away from it. A plunger dial indicator suits most checks on a diameter. A lever-type dial test indicator reaches into bores and close to shoulders.
- Read the feature control frame: the toleranced surface, whether the symbol is circular runout (one arrow) or total runout (two arrows), the tolerance, and the datum features that set the axis, often A or A-B for two bearing journals.
- Support the part on those datum features, or on a setup that stands in for them, such as bench centres when the datums are the centre holes or V-blocks under the datum journals. Add an end stop so the part cannot walk along its axis.
- Clean the part, the supports and the indicator tip, and let the part reach room temperature.
- Mount the indicator on a rigid stand with the arm as short as you can make it. For radial runout, aim the plunger through the axis, square to the surface. For axial runout, set it parallel to the axis, on the face.
- Preload the indicator a little into its travel and set zero anywhere.
- Turn the part slowly through at least one full turn and note the highest and lowest readings. Their difference is the full indicator movement for that circle.
- For circular runout, repeat at several positions along the surface, or at several radii on a face, and judge each circle on its own.
- For total runout, keep turning while you move the indicator along the whole surface, or across the whole face, without resetting zero. The FIM is the spread of all the readings together.
- Compare each FIM with the tolerance and record the readings, the setup and the indicator used.
Circular runout or total runout: what does each one limit?
Both tolerances are defined in ASME Y14.5-2018 and in ISO 1101:2017, which spells it run-out. Neither standard is free to read, so the descriptions below are our own words. Mitutoyo's Quick Guide to Precision Measuring Instruments draws the ISO 1101 zones the same way. The difference between the two tolerances is how much of the surface one reading covers.
| Tolerance | How the indicator moves | Tolerance zone, in words | What it catches |
|---|---|---|---|
| Circular radial runout | Stays at one position along the axis while the part turns, then moves to the next position | At each cross-section, two circles centred on the datum axis whose radii differ by the tolerance | Out-of-roundness of each cross-section and its offset from the axis, together |
| Circular axial runout | Stays at one radius on a face while the part turns | At each radius, two circles a tolerance apart along the axis | Wobble of the face. A face that is evenly dished or coned can still read zero |
| Total radial runout | Travels the full length of the surface, parallel to the datum axis, while the part turns. Zero is not reset | Two cylinders coaxial with the datum axis whose radii differ by the tolerance | Out-of-roundness, offset, taper and bend of the whole surface at once |
| Total axial runout | Travels across the whole face, square to the datum axis, while the part turns. Zero is not reset | Two parallel planes a tolerance apart, square to the datum axis | Flatness of the face and its squareness to the axis, together |
Radial or axial: where should the indicator point?
Radial runout is read across the axis, on a diameter. Aim the plunger through the axis and square to the surface, so that the reading is the change in radius and nothing else.
Axial runout is read along the axis, on a face, with the plunger parallel to the axis. On a cone or any other surface at an angle to the axis, read square to the surface unless the drawing gives a direction.
A lever-type test indicator measures at right angles to the line through its contact point and the pivot of its stylus, so it reads true only when the surface moves in that direction. Set the stylus as close to parallel with the surface as you can. Mitutoyo's Quick Guide gives the correction as the reading times the cosine of the angle: 0.98 at 10°, 0.94 at 20° and 0.87 at 30°. At 30°, a reading of 0.020 mm is really about 0.017 mm.
What sets the axis: centres, V-blocks, a chuck or the datum features?
The drawing's datum axis comes from the datum features, for example the two bearing journals of a shaft. A setup on the bench only stands in for that axis, and each setup stands in a little differently. When a result is close to the tolerance, the setup is often why two inspectors disagree.
| Setup | The axis it gives you | Watch for |
|---|---|---|
| Bench centres | The line through the two centre holes | Right only when the centre holes are the datums, or the datum journals were ground on them. Damaged or dirty centre holes and the runout of the centres themselves add to the reading |
| V-blocks under the datum journals | Two lines of contact on each journal | The part rests on its own surface, so out-of-roundness of the journals moves it as it turns. A lobed journal can make the reading too high or too low. Hold the part against an end stop |
| Chuck or collet on the datum feature | The axis of the jaws as they grip | The chuck's own runout adds to the reading, and the jaws hold only part of the datum feature. Check the chuck with a test bar first |
| Roundness instrument or CMM | An axis computed from points measured on the datum features | Closest to the drawing, but the result depends on the points taken and the fitting method |
How do you read the result? Full indicator movement, with an example
Runout is judged on the full indicator movement (FIM): the highest reading minus the lowest, with zero set anywhere. ASME Y14.5 uses the term FIM. Older drawings and many shops say TIR, for total indicator reading, or FIR, for full indicator reading, and mean the same spread. Mitutoyo's Quick Guide defines the runout value (TIR) as the maximum minus the minimum.
A worked example. A shaft sits in V-blocks under its two datum journals, with an end stop. A dial indicator graduated in 0.001 mm is set once at the start of a bearing seat, then read through a full turn at three positions along the seat. The readings are in the table at the end of this section, and they lead to two different verdicts.
- If the drawing calls for circular radial runout of 0.015 mm, the worst circle reads 0.012 mm and the seat passes.
- If it calls for total radial runout of 0.015 mm, the spread of all the readings is +0.013 − (−0.004) = 0.017 mm and the seat fails.
- The middle of the readings rises along the seat while the spread of each circle stays about the same. That points to a taper, or to an indicator slide that is not parallel to the datum axis. Circular runout cannot see it, and total runout can.
| Position along the seat | Highest reading | Lowest reading | FIM of that circle |
|---|---|---|---|
| 10 mm from the shoulder | +0.006 | −0.004 | 0.010 |
| 40 mm from the shoulder | +0.009 | −0.002 | 0.011 |
| 70 mm from the shoulder | +0.013 | +0.001 | 0.012 |
Runout, roundness and concentricity: how are they related?
Radial runout mixes two things: the out-of-roundness of each cross-section and how far its centre sits from the datum axis. A perfectly round section whose centre is 0.005 mm off the axis reads 0.010 mm, twice the offset, because the indicator sees the high side and the low side in one turn. A section centred on the axis but slightly lobed still reads its form error. Runout alone does not tell you which of the two you have.
Roundness on its own is judged about the section's own centre, with no datum, so a part can be round and still have a large runout. Runout is what a bearing or a seal feels as the shaft turns, which is why it is checked so often on the shop floor.
Concentricity in ASME Y14.5-2009 judged the median points of opposed surface elements against the datum axis, and coaxiality in ISO 1101 judges an axis. Both need many points measured and centres computed, which is a job for a roundness instrument or a CMM rather than a dial indicator. ASME Y14.5-2018 removed concentricity and symmetry altogether, and Mitutoyo's notes on that edition name position and runout as the better options for coaxial features.
Which setup errors change the reading?
- Supporting the part on a diameter that is not a datum feature, or between centres when the datums are the journals.
- An indicator that is not square to the surface, or a test indicator stylus at a steep angle.
- A long, springy indicator arm, or a magnetic base on a surface that moves.
- The part walking along its axis in V-blocks during an axial check. Use an end stop and a light, steady push.
- Reading across a keyway, a flat, a chamfer or a cross hole. Lift the tip over the gap, or measure circles that avoid it.
- Burrs, chips or coolant on the datum journals, in the centre holes or on the V-blocks.
- Turning faster than the needle can follow, so the true peaks are missed.
- A part still warm from the machine, which changes size and shape as it cools.
How good does the indicator need to be?
Runout tolerances are often a few hundredths of a millimetre or less, and the indicator works over a small part of its range. Choose one whose graduation is a small fraction of the tolerance, and know its error over the short span you use, not only over its full travel. The dial indicator guide covers how ISO 463 and ISO 9493 describe those checks.
The fixtures count as well. Centres or V-blocks, and the surface plate under them, carry their own errors into the result. Give them checks of their own and record which ones each measurement used.
Keeping the indicators and fixtures behind a runout check in calibration
Axiospec is calibration management software, and it does not measure runout. It keeps the dial indicators, test indicators, bench centres and V-blocks behind the measurement on one register, each with its calibration history, certificates and next due date, with the interval in days, months or years. A calibration record holds up to 100 named test points with as-found and as-left readings, and an accepted Fail or Damaged result puts the instrument in quarantine. The free plan covers up to 50 active instruments.
Common questions
- What is the difference between circular runout and total runout?
- Circular runout is judged one circle at a time: the indicator stays at one position while the part turns, and each circle's full indicator movement must be within the tolerance. Total runout moves the indicator over the whole surface as the part turns, without resetting zero, so it also catches taper and bend.
- What is the difference between radial and axial runout?
- Radial runout is read across the axis, on a diameter, and shows out-of-roundness and offset from the axis. Axial runout is read along the axis, on a face, and shows how much the face wobbles as the part turns.
- Is TIR the same as runout?
- TIR, total indicator reading, is the shop term for the spread between the highest and the lowest indicator reading, which ASME Y14.5 calls full indicator movement (FIM). Runout is the tolerance, and the FIM is the measured value you compare with it.
- Can runout be measured with the part in V-blocks?
- Yes, with the V-blocks under the datum features, but the V-blocks only approximate the datum axis. Out-of-roundness of the supporting journals enters the reading, so note the setup on the record and use a roundness instrument or a CMM when the result is close to the limit.
- Is runout the same as concentricity?
- No. Runout measures the surface as the part turns and combines out-of-roundness with offset from the axis, while concentricity judged centre points. ASME Y14.5-2018 removed concentricity, and runout or position is used in its place.
- Can a CMM measure runout?
- Yes. A CMM or a roundness instrument builds the datum axis from points on the datum features and works out runout from points on the toleranced surface. The result depends on the number of points and the fitting method, so the program should state both.
Put it into practice
Got a gage list? Send it over and we load it for you, usually in a couple of business days. Free on every plan. Then log every calibration to a tamper-evident audit trail and produce records on demand.
Axiospec is a documentation and workflow tool. It helps you keep clean, traceable, audit-ready records. Certification depends on your own processes, scope and assessor.
Take the audit-prep checklist with you
First the checklist, with each item phrased the way an auditor asks it. Then four short emails with practical tips. You can unsubscribe in one click.
First we email you a link to confirm your address. Nothing else comes until you confirm, and you can unsubscribe from any email after that. See our Privacy Policy.