Skip to content

AQL sampling calculator

Enter the lot size, the inspection level and the AQL. You get the sample size code letter, the sample size and the acceptance and rejection numbers for single sampling under normal inspection. It all runs in your browser.

Your lot

Level II is the one normally used.

Sampling plan

Checking the sample with go/no-go gauges, thread gauges or calipers? Axiospec keeps each one on a register with its calibration history, certificates and next due date.

How the sampling plan is found

The lot size and the inspection level give a sample size code letter in Table I of MIL-STD-105E. The code letter and the AQL then meet in Table II-A, the master table for single sampling under normal inspection. The letter's row gives the sample size, and the cell gives the acceptance number Ac and the rejection number Re.

When the table shows an arrow

Some cells hold an arrow, because the table has no plan for that code letter at that AQL. The standard says to use the first sampling plan the arrow reaches, with the sample size of the new code letter. If that sample size equals or exceeds the lot size, inspect every unit.

Which inspection level to choose

Level II is the general level normally used. Level I gives the same sample or a smaller one for the same lot, and level III the same or a larger one. The special levels S-1 to S-4 keep samples small where larger sampling risks can be tolerated. Destructive or costly tests are a common case.

What the calculator covers

It covers single sampling under normal inspection. Tightened and reduced inspection have their own tables in the standard, and so do double and multiple sampling. MIL-STD-105E was cancelled in 1995, and the Department of Defense still publishes its full text free. If your contract names ANSI/ASQ Z1.4 or ISO 2859-1, take the values from that standard and edition.

Common questions

  • How do I find the sample size for an AQL?

    Find the sample size code letter from the lot size and the inspection level. That letter's row in the master table gives the sample size, and the AQL column gives the acceptance and rejection numbers. The calculator does both lookups in the MIL-STD-105E tables.

  • What do Ac and Re mean?

    Ac is the acceptance number and Re is the rejection number. Accept the lot when the count in the sample is Ac or less, and reject it when the count is Re or more. In these normal inspection plans Re is always Ac plus 1.

  • Why is the sample size not the one for my code letter?

    The table has no plan for that code letter at that AQL, so the cell holds an arrow. The standard says to use the first plan the arrow reaches. The sample size then comes from the new code letter, not the original one.

  • Which standard do the values come from?

    MIL-STD-105E, the cancelled US military standard for sampling by attributes, whose text is free to read. ANSI/ASQ Z1.4 and ISO 2859-1 are sold standards, and their tables are not reproduced here. For a contract, take the values from the standard and edition the contract names.

  • Is anything I enter sent to Axiospec?

    No. The lookup runs in your browser, and nothing you enter is sent to Axiospec.

Keep your inspection gauges in calibration

Axiospec holds each gauge with its calibration history, certificates and next due date, and sends reminders before one falls due. Free for up to 50 instruments.

Got a gage list? Send it over and we load it for you, usually in a couple of business days. Free on every plan.